Home  |  About IMS  |  Monitoring  |  Mesh Blockage  |  Products  |  Contact Us
Pall PCM200 Portable Cleanliness Monitor

The Pall PCM200 is specifically developed as a portable or fixed diagnostic monitoring device that provides an assessment of system fluid cleanliness.

Features

  • Proven mesh blockage technology
  • Results not affected by water or air
  • Monitors dissolved water content
  • Low pressure (<2 bar) on-line or off-line sampling
  • Continuous monitoring
  • 500 test memory
  • Viscosity output in centistokes(cSt)
  • Remote control and data acquisition via PC or PLC

Benefits

As part of continued component cleanliness 'pass off' checks or predictive maintenance programs the PCM200 monitor quickly reports test data so that ongoing assessments can be made.

Early detection of abnormal fluid cleanliness allows for timely investigation and corrective actions to be implemented. The PCM200 can be permanently installed to monitor critical applications (including component test facilities) or used as a portable device for routine condition monitoring of various fluid systems.

The PCM200 has been designed for operators who require a cost-effective, simple to use low-pressure sampler which is portable and can be laboratory based or even integrated into OEM equipment.

The monitor enclosure is manufactured from durable 316 stainless steel and the outer cover has facility for permanent fixing to a bench or test stand. The enclosure is fitted with an indexing handle for both carrying and using as a monitor stand.

Click here if you'd like more information on this product.

Pall PCM200 Specifications

Viscosity range 1.5 - 450cSt
Test time About 6 minutes depending on temperature stability
Operating pressure range 0 to 2 Bar maximum
Output data ISO4406, SAE AS4059E Table 1 (NAS 1638) or SAE AS 4059E Table 2
Monitoring range ISO4406 -/9/7 to -/21/17
Monitoring range SAE AS4059E Table 1 1 to 10 at 6 to 14µm(c) (5 to 15µm)
Monitoring range SAE AS4059E Table 2 >6µm: 1B to 10B and >14µm: 1C to 10C
Seals Fluorocarbon
Fluid temperature range 10 - 80°C (50 - 170°F)
Ambient temperature 50 °C (122°F) maximum
Power supply 92-264VAC (50-60Hz).
18-24VDC